Research Article
Modeling and Design of a Multistream Plate-Fin Heat Exchanger in the Air Separation Units by Pinch Technology
Table 17
The detailed final design of the case study: section III.
| Stream | Passage no | Fin type | Re | h | |
| HP air | 7 | SF 1/4–11.01 | 3531 | 1342 | 3.30 | LP air | 16 | SF 1/8–19.86 | 6543 | 3455 | 2.53 | LPN2 | 7 | SF 1/8–19.86 | 8766 | 2289 | 1.34 | WN2 | 11 | SF 1/9–25.01 | 1234 | 956 | 3.98 | LPO2 | 5 | SF 1/9–25.01 | 7360 | 1098 | 6.72 |
|
|