Research Article

Absorption of Nickel, Chromium, and Iron by the Root Surface of Primary Molars Covered with Stainless Steel Crowns

Table 1

The quantity (in mlwt%) of Ni, Cr, and Fe in the cementum of the mesial root of primary molars.

NiCrFe
SSCIntactP SSCIntactPSSCIntactP

Mean0.860.16<.00010.590.11<.00011.130.20<.0001
N171717171717
SD0.420.100.370.070.770.13
Min0.400.000.200.000.400.00
Max1.500.301.700.202.700.40

Note. SSC: molars covered with stainless steel crowns, Intact: intact molars, P: P value, N: number of molars examined, and SD: standard deviation.