Research Article

Effect of Cavity Configuration (C Factor) on the Marginal Adaptation of Low-Shrinking Composite: A Comparative Ex Vivo Study

Table 1

Specification, constituent, and manufacturers for adhesives and composite resins used in the study.

MaterialSpecificationConstituentManufacturer

Filtek Silorane posterior restorativeVisible light activated silorane based restorative composite(i) Silorane resin3M ESPE Dental Product St. Paul, MN, USA
(ii) Initiating system: camphorquinone, iodonium salt, electron donor
(iii) Fillers: Quartz filler
(iv) Yttrium fluoride with Average Particle Size (μm) 0.47 Filler Load by Weight (%) 76%
(v) Stabilizers
(vi) Pigments

Silorane Adhesive Bond SystemSilorane Self-etch Primer:Phosphorylated methacrylates3M ESPE Dental Products St. Paul, MN, USA
(i) Vitrebond copolymer
(ii) BisGMA
(iii) HEMA
(iv) Water
(v) Ethanol
(vi) Silane-treated silica filler
(vii) Initiators
(viii) Stabilizers
Silorane Adhesive Bond:(i) Hydrophobic dimethacrylate3M ESPE Dental Products St. Paul, MN, USA
(ii) Phosphorylated methacrylates
(iii) TEGDMA
(iv) Silane-treated silica filler
(v) Initiators
(vi) Stabilizer

Filtek Z250Visible light activated methacrylate-based restorative composite(i) The filler is zirconia/silica3M ESPE Dental Products St. Paul, MN, USA
(ii) The inorganic filler loading is 60% by volume “without silane treatment” with particle size range of 0.01 and 3.5 microns.
(iii) It contains Bis-GMA and TEGDMA resins.

Adper Prompt L-PopSelf-etch one-step bonding agentLiquid 1 (red blister):3M ESPE Dental Products St. Paul, MN, USA
(i) Methacrylated phosphoric esters
(ii)Bis-GMA
(iii) Initiators based on camphorquinone
(iv) Stabilizers
Liquid 2 (yellow blister):
(i) Water
(ii) 2-Hydroxyethyl methacrylate (HEMA)
(iii) Polyalkenoic acid
(iv) Stabilizers