Table of Contents Author Guidelines Submit a Manuscript
International Journal of Dentistry
Volume 2016, Article ID 9840594, 10 pages
http://dx.doi.org/10.1155/2016/9840594
Review Article

“Digitally Oriented Materials”: Focus on Lithium Disilicate Ceramics

1Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Fixed Prosthodontics, “Federico II” University of Naples, 80100 Naples, Italy
2Department of Medical Biotechnologies, Division of Fixed Prosthodontics, University of Siena, 53100 Siena, Italy
3Department of Surgical and Morphological Sciences, Dental School, University of Varese, 21100 Varese, Italy

Received 26 February 2016; Accepted 25 July 2016

Academic Editor: Patricia Pereira

Copyright © 2016 Fernando Zarone et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. M. Albakry, M. Guazzato, and M. V. Swain, “Influence of hot pressing on the microstructure and fracture toughness of two pressable dental glass-ceramics,” Journal of Biomedical Materials Research B: Applied Biomaterials, vol. 71, no. 1, pp. 99–107, 2004. View at Publisher · View at Google Scholar · View at Scopus
  2. N. V. Raptis, K. X. Michalakis, and H. Hirayama, “Optical behavior of current ceramic systems,” International Journal of Periodontics and Restorative Dentistry, vol. 26, no. 1, pp. 31–41, 2006. View at Google Scholar · View at Scopus
  3. Y.-M. Chen, R. J. Smales, K. H.-K. Yip, and W.-J. Sung, “Translucency and biaxial flexural strength of four ceramic core materials,” Dental Materials, vol. 24, no. 11, pp. 1506–1511, 2008. View at Publisher · View at Google Scholar · View at Scopus
  4. C. F. J. Stappert, W. Att, T. Gerds, and J. R. Strub, “Fracture resistance of different partial-coverage ceramic molar restorations: an in vitro investigation,” Journal of the American Dental Association, vol. 137, no. 4, pp. 514–522, 2006. View at Publisher · View at Google Scholar · View at Scopus
  5. M. Kern, M. Sasse, and S. Wolfart, “Ten-year outcome of three-unit fixed dental prostheses made from monolithic lithium disilicate ceramic,” Journal of the American Dental Association, vol. 143, no. 3, pp. 234–240, 2012. View at Publisher · View at Google Scholar · View at Scopus
  6. M. Gehrt, S. Wolfart, N. Rafai, S. Reich, and D. Edelhoff, “Clinical results of lithium-disilicate crowns after up to 9 years of service,” Clinical Oral Investigations, vol. 17, no. 1, pp. 275–284, 2013. View at Publisher · View at Google Scholar · View at Scopus
  7. G. Fabbri, R. Sorrentino, M. Brennan, and A. Cerutti, “A novel approach to implant screw-retained restorations: adhesive combination between zirconia frameworks and monolithic lithium disilicate,” The International Journal of Esthetic Dentistry, vol. 9, no. 4, pp. 490–505, 2014. View at Google Scholar · View at Scopus
  8. G. Fabbri, F. Zarone, G. Dellificorelli et al., “Clinical evaluation of 860 anterior and posterior lithium disilicate restorations: retrospective study with a mean follow-up of 3 years and a maximum observational period of 6 years,” The International Journal of Periodontics & Restorative Dentistry, vol. 34, no. 2, pp. 165–177, 2014. View at Publisher · View at Google Scholar
  9. D. Guichet, “Digitally enhanced dentistry: the power of digital design,” Journal of the California Dental Association, vol. 43, no. 3, pp. 135–141, 2015. View at Google Scholar · View at Scopus
  10. S. Reich, “Tooth-colored CAD/CAM monolithic restorations,” International Journal of Computerized Dentistry, vol. 18, no. 2, pp. 131–146, 2015. View at Google Scholar · View at Scopus
  11. I. Sailer, N. A. Makarov, D. S. Thoma, M. Zwahlen, and B. E. Pjetursson, “All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: single crowns (SCs),” Dental Materials, vol. 31, no. 6, pp. 603–623, 2015. View at Publisher · View at Google Scholar · View at Scopus
  12. I. Denry and J. A. Holloway, “Ceramics for dental applications: a review,” Materials, vol. 3, no. 1, pp. 351–368, 2010. View at Publisher · View at Google Scholar · View at Scopus
  13. W. Lien, H. W. Roberts, J. A. Platt, K. S. Vandewalle, T. J. Hill, and T.-M. G. Chu, “Microstructural evolution and physical behavior of a lithium disilicate glass-ceramic,” Dental Materials, vol. 31, no. 8, pp. 928–940, 2015. View at Publisher · View at Google Scholar · View at Scopus
  14. M. Lupu and R. A. Giordano, “Flexural strength of CAD/CAM ceramic framework materials,” Journal of Dental Research, vol. 88, p. 224, 2007. View at Google Scholar
  15. K. Fischer, P. Bühler-Zemp, and T. Völkel, “IPS e.max CAD,” Scientific Documentation, Ivoclar Vivadent, Schaan, Liechtenstein, 2005. View at Google Scholar
  16. P. Bühler-Zemp, T. Völkel, and K. Fischer, Scientific Documentation IPS e.Max Press, Ivoclar Vivadent, Schaan, Liechtenstein, 2011.
  17. X.-F. Song, H.-T. Ren, and L. Yin, “Machinability of lithium disilicate glass ceramic in in vitro dental diamond bur adjusting process,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 53, pp. 78–92, 2016. View at Publisher · View at Google Scholar · View at Scopus
  18. F. Al Mansour, N. Karpukhina, S. Grasso, R. M. Wilson, M. J. Reece, and M. J. Cattell, “The effect of spark plasma sintering on lithium disilicate glass-ceramics,” Dental Materials, vol. 31, no. 10, pp. e226–e235, 2015. View at Publisher · View at Google Scholar · View at Scopus
  19. H. W. A. Wiskott, J. I. Nicholls, and U. C. Belser, “Stress fatigue: basic principles and prosthodontic implications,” The International Journal of Prosthodontics, vol. 8, pp. 105–116, 1995. View at Google Scholar
  20. K. Zhao, Y.-R. Wei, Y. Pan, X.-P. Zhang, M. V. Swain, and P. C. Guess, “Influence of veneer and cyclic loading on failure behavior of lithium disilicate glass-ceramic molar crowns,” Dental Materials, vol. 30, no. 2, pp. 164–171, 2014. View at Publisher · View at Google Scholar · View at Scopus
  21. B. Seydler, S. Rues, D. Müller, and M. Schmitter, “In vitro fracture load of monolithic lithium disilicate ceramic molar crowns with different wall thicknesses,” Clinical Oral Investigations, vol. 18, no. 4, pp. 1165–1171, 2014. View at Publisher · View at Google Scholar · View at Scopus
  22. M. Dhima, A. B. Carr, T. J. Salinas, C. Lohse, L. Berglund, and K.-A. Nan, “Evaluation of fracture resistance in aqueous environment under dynamic loading of lithium disilicate restorative systems for posterior applications. Part 2,” Journal of Prosthodontics, vol. 23, no. 5, pp. 353–357, 2014. View at Publisher · View at Google Scholar · View at Scopus
  23. M. Rosentritt, M. Behr, R. Gebhard, and G. Handel, “Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures,” Dental Materials, vol. 22, no. 2, pp. 176–182, 2006. View at Publisher · View at Google Scholar · View at Scopus
  24. N. Nawafleh, M. Hatamleh, S. Elshiyab, and F. Mack, “Lithium disilicate restorations fatigue testing parameters: a systematic review,” Journal of Prosthodontics, vol. 25, no. 2, pp. 116–126, 2016. View at Publisher · View at Google Scholar · View at Scopus
  25. J.-O. Clausen, M. Abou Tara, and M. Kern, “Dynamic fatigue and fracture resistance of non-retentive all-ceramic full-coverage molar restorations. Influence of ceramic material and preparation design,” Dental Materials, vol. 26, no. 6, pp. 533–538, 2010. View at Publisher · View at Google Scholar · View at Scopus
  26. S. Pieger, A. Salman, and A. S. Bidra, “Clinical outcomes of lithium disilicate single crowns and partial fixed dental prostheses: a systematic review,” Journal of Prosthetic Dentistry, vol. 112, no. 1, pp. 22–30, 2014. View at Publisher · View at Google Scholar · View at Scopus
  27. M. Mitsias, S.-O. Koutayas, S. Wolfart, and M. Kern, “Influence of zirconia abutment preparation on the fracture strength of single implant lithium disilicate crowns after chewing simulation,” Clinical Oral Implants Research, vol. 25, no. 6, pp. 675–682, 2014. View at Publisher · View at Google Scholar · View at Scopus
  28. S. Chitmongkolsuk, G. Heydecke, C. Stappert, and J. R. Strub, “Fracture strength of all-ceramic lithium disilicate and porcelain-fused-to-metal bridges for molar replacement after dynamic loading,” The European Journal of Prosthodontics and Restorative Dentistry, vol. 10, no. 1, pp. 15–22, 2002. View at Google Scholar · View at Scopus
  29. S. Schultheis, J. R. Strub, T. A. Gerds, and P. C. Guess, “Monolithic and bi-layer CAD/CAM lithium-disilicate versus metal-ceramic fixed dental prostheses: comparison of fracture loads and failure modes after fatigue,” Clinical Oral Investigations, vol. 17, no. 5, pp. 1407–1413, 2013. View at Publisher · View at Google Scholar · View at Scopus
  30. M. Rosentritt, G. Siavikis, M. Behr, C. Kolbeck, and G. Handel, “Approach for valuating the significance of laboratory simulation,” Journal of Dentistry, vol. 36, no. 12, pp. 1048–1053, 2008. View at Publisher · View at Google Scholar · View at Scopus
  31. E. Yassini, M. Mirzaei, A. Alimi, and M. Rahaeifard, “Investigation of the fatigue behavior of adhesive bonding of the lithium disilicate glass ceramic with three resin cements using rotating fatigue method,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 61, pp. 62–69, 2016. View at Publisher · View at Google Scholar · View at Scopus
  32. R. Frankenberger, V. E. Hartmann, M. Krech et al., “Adhesive luting of new CAD/CAM materials,” International Journal of Computing, vol. 18, pp. 9–20, 2015. View at Google Scholar
  33. A. O. Carvalho, G. Bruzi, R. E. Anderson, H. P. Maia, M. Giannini, and P. Magne, “Influence of adhesive core buildup designs on the resistance of endodontically treated molars restored with lithium disilicate CAD/CAM crowns,” Operative Dentistry, vol. 41, pp. 76–82, 2016. View at Google Scholar
  34. A. O. Carvalho, G. Bruzi, M. Giannini, and P. Magne, “Fatigue resistance of CAD/CAM complete crowns with a simplified cementation process,” The Journal of Prosthetic Dentistry, vol. 111, no. 4, pp. 310–317, 2014. View at Publisher · View at Google Scholar · View at Scopus
  35. D. O. Dogan, O. Gorler, B. Mutaf, M. Ozcan, G. B. Eyuboglu, and M. Ulgey, “Fracture resistance of molar crowns fabricated with monolithic all-ceramic CAD/CAM materials cemented on titanium abutments: an in vitro study,” Journal of Prosthodontics, 2015. View at Publisher · View at Google Scholar · View at Scopus
  36. T. Joda, A. Bürki, S. Bethge, U. Brägger, and P. Zysset, “Stiffness, strength, and failure modes of implant-supported monolithic lithium disilicate crowns: influence of titanium and zirconia abutments,” The International Journal of Oral & Maxillofacial Implants, vol. 30, no. 6, pp. 1272–1279, 2015. View at Publisher · View at Google Scholar
  37. C. G. Figueiredo-Pina, N. Patas, J. Canhoto et al., “Tribological behaviour of unveneered and veneered lithium disilicate dental material,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 53, pp. 226–238, 2016. View at Publisher · View at Google Scholar · View at Scopus
  38. N. C. Lawson, S. Janyavula, S. Syklawer, E. A. McLaren, and J. O. Burgess, “Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing,” Journal of Dentistry, vol. 42, no. 12, pp. 1586–1591, 2014. View at Publisher · View at Google Scholar · View at Scopus
  39. R. Amer, D. Kürklü, and W. Johnston, “Effect of simulated mastication on the surface roughness of three ceramic systems,” Journal of Prosthetic Dentistry, vol. 114, no. 2, pp. 260–265, 2015. View at Publisher · View at Google Scholar · View at Scopus
  40. A. Lee, M. Swain, L. He, and K. Lyons, “Wear behavior of human enamel against lithium disilicate glass ceramic and type III gold,” Journal of Prosthetic Dentistry, vol. 112, no. 6, pp. 1399–1405, 2014. View at Publisher · View at Google Scholar · View at Scopus
  41. V. Preis, F. Weiser, G. Handel, and M. Rosentritt, “Wear performance of monolithic dental ceramics with different surface treatments,” Quintessence International, vol. 44, no. 5, pp. 393–405, 2013. View at Google Scholar · View at Scopus
  42. Z. Peng, M. Izzat Abdul Rahman, Y. Zhang, and L. Yin, “Wear behavior of pressable lithium disilicate glass ceramic,” Journal of Biomedical Materials Research Part B: Applied Biomaterials, vol. 104, no. 5, pp. 968–978, 2016. View at Publisher · View at Google Scholar
  43. W. H. Mörmann, B. Stawarczyk, A. Ender, B. Sener, T. Attin, and A. Mehl, “Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 20, pp. 113–125, 2013. View at Publisher · View at Google Scholar · View at Scopus
  44. B. Stawarczyk, A. Liebermann, M. Eichberger, and J.-F. Güth, “Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites,” Journal of the Mechanical Behavior of Biomedical Materials, vol. 55, pp. 1–11, 2015. View at Publisher · View at Google Scholar · View at Scopus
  45. C. A. Neis, N. L. G. Albuquerque, I. de Souza Albuquerque et al., “Surface treatments for repair of feldspathic, leucite- and lithium disilicate-reinforced glass ceramics using composite resin,” Brazilian Dental Journal, vol. 26, no. 2, pp. 152–155, 2015. View at Publisher · View at Google Scholar · View at Scopus
  46. E. Anadioti, S. A. Aquilino, D. G. Gratton et al., “3D and 2D marginal fit of pressed and CAD/CAM lithium disilicate crowns made from digital and conventional impressions,” Journal of Prosthodontics, vol. 23, no. 8, pp. 610–617, 2014. View at Publisher · View at Google Scholar · View at Scopus
  47. F. D. Neves, C. J. Prado, M. S. Prudente et al., “Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique,” Journal of Prosthetic Dentistry, vol. 112, no. 5, pp. 1134–1140, 2014. View at Publisher · View at Google Scholar
  48. J. Ng, D. Ruse, and C. Wyatt, “A comparison of the marginal fit of crowns fabricated with digital and conventional methods,” Journal of Prosthetic Dentistry, vol. 112, no. 3, pp. 555–560, 2014. View at Publisher · View at Google Scholar · View at Scopus
  49. E. Anadioti, S. A. Aquilino, D. G. Gratton et al., “Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions,” Journal of Prosthetic Dentistry, vol. 113, no. 4, pp. 304–309, 2015. View at Publisher · View at Google Scholar · View at Scopus
  50. D. P. Alfaro, N. D. Ruse, R. M. Carvalho, and C. C. Wyatt, “Assessment of the internal fit of lithium disilicate crowns using micro-CT,” Journal of Prosthodontics, vol. 24, no. 5, pp. 381–386, 2015. View at Publisher · View at Google Scholar · View at Scopus
  51. T. Abdel-Azim, K. Rogers, E. Elathamna, A. Zandinejad, M. Metz, and D. Morton, “Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners,” Journal of Prosthetic Dentistry, vol. 114, no. 4, pp. 554–559, 2015. View at Publisher · View at Google Scholar · View at Scopus
  52. O. Schaefer, M. Decker, F. Wittstock, H. Kuepper, and A. Guentsch, “Impact of digital impression techniques on the adaption of ceramic partial crowns in vitro,” Journal of Dentistry, vol. 42, no. 6, pp. 677–683, 2014. View at Publisher · View at Google Scholar · View at Scopus
  53. M.-K. Ji, J.-H. Park, S.-W. Park, K.-D. Yun, G.-J. Oh, and H.-P. Lim, “Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown,” Journal of Advanced Prosthodontics, vol. 7, no. 4, pp. 271–277, 2015. View at Publisher · View at Google Scholar · View at Scopus
  54. S.-J. Nam, M.-J. Yoon, W.-H. Kim, G.-J. Ryu, M.-K. Bang, and J.-B. Huh, “Marginal and internal fit of conventional metal-ceramic and lithium disilicate CAD/CAM crowns,” The International Journal of Prosthodontics, vol. 28, no. 5, pp. 519–521, 2015. View at Publisher · View at Google Scholar · View at Scopus
  55. P. C. Guess, T. Vagkopoulou, Y. Zhang, M. Wolkewitz, and J. R. Strub, “Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue,” Journal of Dentistry, vol. 42, no. 2, pp. 199–209, 2014. View at Publisher · View at Google Scholar · View at Scopus
  56. H. A. Mously, M. Finkelman, R. Zandparsa, and H. Hirayama, “Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique,” Journal of Prosthetic Dentistry, vol. 112, no. 2, pp. 249–256, 2014. View at Publisher · View at Google Scholar · View at Scopus
  57. R. L. W. Messer, P. E. Lockwood, J. C. Wataha, J. B. Lewis, S. Norris, and S. Bouillaguet, “In vitro cytotoxicity of traditional versus contemporary dental ceramics,” Journal of Prosthetic Dentistry, vol. 90, no. 5, pp. 452–458, 2003. View at Publisher · View at Google Scholar · View at Scopus
  58. S. Tetè, V. L. Zizzari, B. Borelli et al., “Proliferation and adhesion capability of human gingival fibroblasts onto Zirconia, lithium disilicate and feldspathic veneering ceramic in vitro,” Dental Materials Journal, vol. 33, no. 1, pp. 7–15, 2014. View at Publisher · View at Google Scholar · View at Scopus
  59. A. Forster, K. Ungvári, Á. Györgyey, Á. Kukovecz, K. Turzó, and K. Nagy, “Human epithelial tissue culture study on restorative materials,” Journal of Dentistry, vol. 42, no. 1, pp. 7–14, 2014. View at Publisher · View at Google Scholar · View at Scopus
  60. R. W. K. Li, T. W. Chow, and J. P. Matinlinna, “Ceramic dental biomaterials and CAD/CAM technology: state of the art,” Journal of Prosthodontic Research, vol. 58, no. 4, pp. 208–216, 2014. View at Publisher · View at Google Scholar · View at Scopus
  61. K. Ariaans, N. Heussen, H. Schiffer et al., “Use of molecular indicators of inflammation to assess the biocompatibility of all-ceramic restorations,” Journal of Clinical Periodontology, vol. 43, no. 2, pp. 173–179, 2016. View at Publisher · View at Google Scholar
  62. S. Toksavul and M. Toman, “A short-term clinical evaluation of IPS empress 2 crowns,” International Journal of Prosthodontics, vol. 20, no. 2, pp. 168–172, 2007. View at Google Scholar · View at Scopus
  63. P. Marquardt and J. R. Strub, “Survival rates of IPS Empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study,” Quintessence International, vol. 37, no. 4, pp. 253–259, 2006. View at Google Scholar · View at Scopus
  64. J. H. Kim, S.-J. Lee, J. S. Park, and J. J. Ryu, “Fracture load of monolithic CAD/CAM lithium disilicate ceramic crowns and veneered zirconia crowns as a posterior implant restoration,” Implant Dentistry, vol. 22, no. 1, pp. 66–70, 2013. View at Publisher · View at Google Scholar · View at Scopus
  65. N. R. F. A. Silva, V. P. Thompson, G. B. Valverde et al., “Comparative reliability analyses of zirconium oxide and lithium disilicate restorations in vitro and in vivo,” Journal of the American Dental Association (1939), vol. 142, supplement 2, pp. 4S–9S, 2011. View at Google Scholar · View at Scopus
  66. J. F. Esquivel-Upshaw, K. J. Anusavice, H. Young, J. Jones, and C. Gibbs, “Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs,” International Journal of Prosthodontics, vol. 17, no. 4, pp. 469–475, 2004. View at Google Scholar · View at Scopus
  67. P. Simeone and S. Gracis, “Eleven-year retrospective survival study of 275 veneered lithium disilicate single crowns,” The International Journal of Periodontics and Restorative Dentistry, vol. 35, no. 5, pp. 685–694, 2015. View at Google Scholar
  68. M. Valenti and A. Valenti, “Retrospective survival analysis of 110 lithium disilicate crowns with feather-edge marginal preparation,” The International Journal of Esthetic Dentistry, vol. 10, no. 2, pp. 246–257, 2015. View at Google Scholar · View at Scopus
  69. P. C. Guess, C. F. Selz, Y.-N. Steinhart, S. Stampf, and J. R. Strub, “Prospective clinical split-mouth study of pressed and CAD/CAM all-ceramic partial-coverage restorations: 7-year results,” The International Journal of Prosthodontics, vol. 26, no. 1, pp. 21–25, 2013. View at Publisher · View at Google Scholar · View at Scopus
  70. M. Sasse, A. Krummel, K. Klosa, and M. Kern, “Influence of restoration thickness and dental bonding surface on the fracture resistance of full-coverage occlusal veneers made from lithium disilicate ceramic,” Dental Materials, vol. 31, no. 8, pp. 907–915, 2015. View at Publisher · View at Google Scholar · View at Scopus
  71. B. Taskonak and A. Sertgöz, “Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures,” Dental Materials, vol. 22, no. 11, pp. 1008–1013, 2006. View at Publisher · View at Google Scholar · View at Scopus
  72. M. Makarouna, K. Ullmann, K. Lazarek, and K. W. Boening, “Six-year clinical performance of lithium disilicate fixed partial dentures,” The International Journal of Prosthodontics, vol. 24, no. 3, pp. 204–206, 2011. View at Google Scholar · View at Scopus
  73. M. F. Solá-Ruiz, E. Lagos-Flores, J. L. Román-Rodriguez, J. D. R. Highsmith, A. Fons-Font, and M. Granell-Ruiz, “Survival rates of a lithium disilicate-based core ceramic for three-unit esthetic fixed partial dentures: a 10-year prospective study,” The International Journal of Prosthodontics, vol. 26, no. 2, pp. 175–180, 2013. View at Publisher · View at Google Scholar · View at Scopus
  74. P. C. Guess, R. A. Zavanelli, N. R. Silva, E. A. Bonfante, P. Coehlo, and V. P. Thompson, “Monolithic CAD/CAM lithium dislocate versus veneered Y-TZP crowns: comparison of failure modes and reliability after fatigue,” The International Journal of Prosthodontics, vol. 23, pp. 434–442, 2010. View at Google Scholar
  75. K. Zhao, Y. Pan, P. C. Guess, X.-P. Zhang, and M. V. Swain, “Influence of veneer application on fracture behavior of lithium-disilicate-based ceramic crowns,” Dental Materials, vol. 28, no. 6, pp. 653–660, 2012. View at Publisher · View at Google Scholar · View at Scopus
  76. B. E. Pjetursson, U. Brägger, N. P. Lang, and M. Zwahlen, “Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs),” Clinical Oral Implants Research, vol. 18, no. 3, pp. 97–113, 2007. View at Publisher · View at Google Scholar · View at Scopus
  77. C. A. Barwacz, M. Hernandez, and R. H. Husemann, “Minimally invasive preparation and design of a cantilevered, all-ceramic, resin-bonded, fixed partial denture in the esthetic zone: a case report and descriptive review,” Journal of Esthetic and Restorative Dentistry, vol. 26, no. 5, pp. 314–323, 2014. View at Publisher · View at Google Scholar · View at Scopus
  78. M. Sasse, S. Eschbach, and M. Kern, “Randomized clinical trial on single retainer all-ceramic resin-bonded fixed partial dentures: influence of the bonding system after up to 55 months,” Journal of Dentistry, vol. 40, no. 9, pp. 783–786, 2012. View at Publisher · View at Google Scholar · View at Scopus
  79. Q. Sun, L. Chen, L. Tian, and B. Xu, “Single-tooth replacement in the anterior arch by means of a cantilevered IPS e.max Press veneer-retained fixed partial denture: case series of 35 patients,” The International Journal of Prosthodontics, vol. 26, no. 2, pp. 181–187, 2013. View at Publisher · View at Google Scholar · View at Scopus
  80. M. Foitzik, A. M. Lennon, and T. Attin, “Successful use of a single-retainer all-ceramic resin-bonded fixed partial denture for replacement of a maxillary canine: a clinical report,” Quintessence International, vol. 38, no. 3, pp. 241–246, 2007. View at Google Scholar · View at Scopus
  81. S. Reich and O. Schierz, “Chair-side generated posterior lithium disilicate crowns after 4 years,” Clinical Oral Investigations, vol. 17, no. 7, pp. 1765–1772, 2013. View at Publisher · View at Google Scholar · View at Scopus
  82. T. A. Sulaiman, A. J. Delgado, and T. E. Donovan, “Survival rate of lithium disilicate restorations at 4 years: a retrospective study,” Journal of Prosthetic Dentistry, vol. 114, no. 3, pp. 364–366, 2015. View at Publisher · View at Google Scholar · View at Scopus
  83. T. Albrecht, A. Kirsten, H. F. Kappert, and H. Fischer, “Fracture load of different crown systems on zirconia implant abutments,” Dental Materials, vol. 27, no. 3, pp. 298–303, 2011. View at Publisher · View at Google Scholar · View at Scopus
  84. L. F. Cooper, C. Stanford, J. Feine, and M. McGuire, “Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results,” The Journal of Prosthetic Dentistry, vol. 116, no. 1, pp. 33–39, 2016. View at Publisher · View at Google Scholar
  85. A. Pozzi, M. Tallarico, and A. Barlattani, “Monolithic lithium disilicate full-contour crowns bonded on CAD/CAM zirconia complete-arch implant bridges with 3 to 5 years of follow-up,” Journal of Oral Implantology, vol. 41, no. 4, pp. 450–458, 2015. View at Publisher · View at Google Scholar · View at Scopus