Research Article
Shaping Ability of Superelastic and Controlled Memory Nickel-Titanium File Systems: An In Vitro Study
Table 2
Comparison between the instruments of the area removed2 (mm2) from canal walls.
| Segments | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| Outer wall | | F360 | 0.03 ± 0.01 | 0.04 ± 0.02 | 0.06 ± 0.02 | 0.07 ± 0.01 | 0.07 ± 0.02 | 0.05 ± 0.02 | 0.08 ± 0.03 | 0.13 ± 0.02 | 0.16 ± 0.03 | 0.16 ± 0.03 | HyFlex®CM™ | 0.03 ± 0.01 | 0.03 ± 0.02 | 0.06 ± 0.02 | 0.07 ± 0.02 | 0.05 ± 0.02 | 0.04 ± 0.01 | 0.08 ± 0.01 | 0.11 ± 0.02 | 0.14 ± 0.02 | 0.15 ± 0.02 | P values | 0.812 | 0.439 | 0.592 | 0.585 | 0.301 | 0.133 | 0.319 | 0.017 | 0.055 | 0.135 |
| Inner wall | | F360 | 0.02 ± 0.01 | 0.03 ± 0.01 | 0.03 ± 0.01 | 0.04 ± 0.02 | 0.09 ± 0.03 | 0.13 ± 0.03 | 0.12 ± 0.02 | 0.10 ± 0.01 | 0.10 ± 0.01 | 0.09 ± 0.02 | HyFlex®CM™ | 0.03 ± 0.01 | 0.04 ± 0.02 | 0.03 ± 0.01 | 0.05 ± 0.02 | 0.10 ± 0.02 | 0.13 ± 0.02 | 0.10 ± .002 | 0.08 ± 0.01 | 0.08 ± 0.02 | 0.07 ± 0.02 | values | 0.218 | 0.908 | 0.540 | 0.966 | 0.254 | 0.909 | 0.086 | 0.021 | 0.019 | 0.066 |
|
|
2Mean ± standard deviation; values are statistically significant. |