Research Article
Effect on Physical and Mechanical Properties of Conventional Glass Ionomer Luting Cements by Incorporation of All-Ceramic Additives: An In Vitro Study
Table 3
Film thickness and setting time of samples in Groups 1 and 2.
| Group 1 | Group 2 | | Film thickness (μ) | Initial setting time (min) | Final setting time (min) | | Film thickness (μ) | Initial setting time (min) | Final setting time (min) |
| Control | 19 | 3.42 | 5.38 | Control | 16 | 2.37 | 4.45 | Experimental GIC 1 | 34.5∗ | 5.19∗ | 7.13∗ | Experimental GIC 1 | 38∗ | 4.08∗ | 6.14∗ | Experimental GIC 2 | 42∗ | 5.48∗ | 8.09∗ | Experimental GIC 2 | 41∗ | 4.11∗ | 7.11∗ | Experimental GIC 3 | 52.5∗ | 5.50∗ | 8.21∗ | Experimental GIC 3 | 51∗ | 4.16∗ | 7.12∗ | Experimental GIC 4 | 35∗ | 5.2∗ | 7.14∗ | Experimental GIC 4 | 37∗ | 4.09∗ | 6.06∗ | Experimental GIC 5 | 42∗ | 5.48∗ | 7.58∗ | Experimental GIC 5 | 42∗ | 4.10∗ | 7.10∗ | Experimental GIC 6 | 52∗ | 5.50∗ | 8.21∗ | Experimental GIC 6 | 52∗ | 4.14∗ | 7.09∗ |
|
|
∗The symbol indicated that there was significant difference between the experimental GIC and control within the group, ( ), n = 6. |