Research Article

Stress Distribution in 5-Unit Fixed Partial Dentures with a Pier Abutment and Rigid and Nonrigid Connectors with Two Different Occlusal Schemes: A Three-Dimensional Finite Element Analysis

Table 5

Von Mises stress and strain values in FPD with RC and group function occlusal scheme.

VariableComponentMaximum valueLocation of maximum valueMinimum valueLocation of minimum value

StressEntire model73.035The buccal surface of the first premolar and first molar1.352The occlusal surface of the second molar
Tooth32.927The buccal surface of the second premolar0.288The distal root of the second molar
FPD56.344The lingual surface of the canine0.653The mesial surface of the canine and occlusal surface of the second molar
Metal framework114.58The mesial surface of the first molar and the distal surface of the second premolar2.884The occlusal surface of the second molar

StrainEntire model0.002The distal surface of the second premolar1.2661e − 5The mesial surface of the canine and occlusal surface of the second molar
Tooth0.001The buccal surface of the canine1.915The occlusal surface of the second molar
FPD0.004The lingual surface of the canine0.001The mesial surface of the second molar
Metal framework0.002The distal surface of the canine1.572The occlusal surface of the second molar