Research Article

Synthesis of 1,2,3-Triazole Derivatives and Its Evaluation as Corrosion Inhibitors for Carbon Steel

Table 5

Inhibitor efficiencies and corrosion rates to carbon steel in 1.0 mol L–1 HCl aqueous solution in absence and presence of 250 mg L–1 of inhibitors during 4 h, varying temperatures.

TemperatureInhibitor.Error
()(mm/y)()()

25Blank16.0
11.789.21.5
20.397.90.6

35Blank33.6
13.689.40.6
20.897.61.6

45Blank66.1
15.991.10.4
22.396.50.2

55Blank99.8
113.087.00.3
25.494.60.3