Research Article

Detection of Selenium and Nickel Metal Ion in Water Using Mn3O4-Cn-Modified Electrode

Table 2

Analytical results of real water samples.

Metal ionsOn-site collection of samplesAdded in sample, µg/LDetermined in sample µg/LRecovery (%)

Ni (II)Tap water1010.5102
Se (IV)9.7597
ICP-MS10.3101

Se (IV)Site 11028.6 ± 0.03120
Site 218.67 ± 0.05115
Site 314.8 ± 0.06110
Site 417.6 ± 0.03115

Ni (II)Site 11031.2 ± 0.12125
Site 235.3 ± 1.3111
Site 328.9 ± 0.7117
Site 430.4 ± 0.01110

ICP-MSSite 1, Se1027.5 ± 0.037120
Site 2, Ni32.2 ± 0.075111