Mean, bias, precision, and accuracy of GFR estimates within two GFR subgroups.

VariableGFR < 60 ml/min/1.73 m2  GFR ≥ 60 ml/min/1.73 m2  (

GFR
(ml/min/1.73 m2)
 Measured33.19 ± 10.3978.32 ± 22.61
 CGBSA33.53 ± 10.7968.92 ± 21.10
 4-MDRD30.24 ± 10.2759.10 ± 21.35
 CKD-EPI30.95 ± 11.1463.00 ± 23.49
Median bias
 CGBSA−0.99 (−9.6, 19.81)−9.80 (−33.00, 27.35)
 4-MDRD−2.60 (−17.10, 10.20)−19.70 (−55.80, 23.60)
 CKD-EPI−1.80 (−15.10, 13.20)−14.70 (−48.80, 32.60)
Mean difference
 CGBSA0.34 ± 7.04−9.40 ± 18.53
 4-MDRD−2.95 ± 6.1319.22 ± 20.11
 CKD-EPI−2.24 ± 6.22−15.32 ± 20.86
Accuracy within 10
 CGBSA24.440.0
 4-MDRD31.720.0
 CKD-EPI31.710.0
Accuracy within 30
 CGBSA63.470.0
 4-MDRD65.980.0
 CKD-EPI65.980.0

Mean CGBSA GFR versus measured GFR , mean 4-MDRD GFR versus measured GFR , and mean CKD-EPI GFR versus measured GFR .