Research Article

Adaptive Fringe Projection for 3D Shape Measurement with Large Reflectivity Variations by Using Image Fusion and Predicted Search

Table 4

Evaluation and analysis of the point cloud by the traditional ADFP method for Figure 15.

DirectionMaximal value (mm)Average error (mm)Standard deviation (mm)

Negative directionāˆ’3.9525āˆ’0.45870.4720
Absolute direction3.95250.00880.0843