Research Article

Low-Glare Freeform-Surfaced Street Light Luminaire Optimization to Meet Enhanced Road Lighting Standards

Table 2

DIALux simulation results of the proposed change in light bulb position in the luminaire with respect to the requirements of the CIE M3 class standard.

Light bulb positionUoULTI
≥0.4≥0.6≤15

(0, 0, 0)0.410.6214.5
(−5, 0, 0)0.370.6822
(0, 5, 0)0.400.7615
(5, 0, 0)0.430.5510
(0, −5, 0)0.410.7313
Optimal position (−0.2, 1.2, 0)0.470.799.5