Clinical Study
Flexible Fiber Optic Carbon-Dioxide Laser Assisted Stapedotomy in Otosclerosis
Table 1
Comparative analysis of hearing results of patients with laser stapedotomy before and after surgery.
| | Preoperative | Postoperative | | | | Min | Max | | Min | Max |
| AC threshold | | | | | | | | 250 Hz | 58.96 ± 12.63 | 35 | 95 | 28.79 ± 9.60 | 10 | 45 | <0.001 | 500 Hz | 56.37 ± 12.31 | 35 | 85 | 26.55 ± 11.26 | 10 | 55 | <0.001 | 1000 Hz | 52.93 ± 12.78 | 30 | 85 | 25.68 ± 12.79 | 10 | 60 | <0.001 | 2000 Hz | 49.13 ± 14.58 | 20 | 75 | 28.27 ± 13.84 | 5 | 65 | <0.001 | 4000 Hz | 50.34 ± 23.67 | 15 | 95 | 37 ± 4120.64 | 5 | 90 | <0.001 | 6000 Hz | 54.65 ± 29.04 | 10 | 110 | 46.37 ± 21.95 | 15 | 95 | 0.225 |
| Average ACT | 53.41 ± 11.81 | 32 | 80 | 26.37 ± 11.04 | 10 | 60 | <0.001 |
| BC threshold | | | | | | | | 500 Hz | 17.62 ± 10.08 | 0 | 40 | 13.72 ± 9.19 | 0 | 35 | 0.129 | 1000 Hz | 15.62 ± 9.01 | 0 | 30 | 14.27 ± 10.84 | 0 | 40 | 0.612 | 2000 Hz | 22.06 ± 13.29 | 5 | 50 | 19.48 ± 13.81 | 0 | 60 | 0.473 | 4000 Hz | 21.20 ± 19.42 | 0 | 65 | 21.37 ± 21.10 | 0 | 70 | 1.000 |
| Average BCT | 20.13 ± 8.59 | 5 | 32 | 16.68 ± 12.00 | 0 | 60 | 0.213 |
| SRT | 60.68 ± 12.86 | 30 | 85 | 34.34 ± 12.49 | 20 | 75 | <0.001 |
| SDS | 87.65 ± 19.66 | 80 | 96 | 88.89 ± 21.88 | 76 | 96 | 0.303 |
| Air-bone gap | | | | | | | | 500 Hz | 38.44 ± 11.73 | 15 | 60 | 12.96 ± 7.56 | 0 | 30 | <0.001 | 1000 Hz | 37.93 ± 9.86 | 25 | 55 | 12.20 ± 7.27 | 0 | 30 | <0.001 | 2000 Hz | 27.41 ± 11.22 | 5 | 45 | 9.13 ± 6.50 | 0 | 30 | <0.001 | 4000 Hz | 29.48 ± 13.90 | 5 | 65 | 15.93 ± 9.98 | 0 | 30 | <0.001 |
| Average A-B gap | 34 ± 9.92 | 17 | 62 | 12.03 ± 6.02 | 0 | 25 | <0.001 |
|
|