Research Article

Analysis of Humid Air Turbine Cycle with Low- or Medium-Temperature Solar Energy

Table 2

The data of every state point parameters for hat cycle with solar energy.

Condition
PointPressure (MPa)Temperature ( )Flow rate (kg/s)Enthalpy change (kJ/ kg )Entropy change (kJ/(kg K))Exergy (kJ/ kg)Total exergy (kW)

11.013215.050.320000
23.7537170.250.32158.100.0631139.97040.32
33.641165.050.3250.42−0.2057109.75519.06
413.489247.250.32238.12−0.1382278.013985.87
513.084365.050.3250.41−0.5742215.910861.93
612.8226133.859.37499.000.7318288.117072.65
712.438560.659.371020.771.6225553.232767.56
812.06481100.060.361878.392.54751144.368793.08
91.0769585.660.361158.122.6379398.023861.72
101.0446184.660.36648.761.8436117.56988.94
111.013286.760.36530.751.562980.44781.75
1213.084315.09.371.16−0.00021.211.26
1333.48951.711.80156.080.499212.2144.34
1432.4843160.211.80615.061.7175120.21418.32
1533.48951.712.37156.080.499212.2151.32
1632.4843228.312.37919.332.3691236.72928.97
1733.48951.79.31156.080.499212.2112.36
1832.4843228.39.31919.332.3691236.72174.86
1913.0843204.743.54810.542.1516190.68258.80
2013.084362.734.17200.530.6416.1548.17
2133.48951.710.05156.080.499212.2122.41
2232.4843204.710.05811.282.1484192.21922.43