Research Article

A Comprehensive Review and Analysis of Solar Photovoltaic Array Configurations under Partial Shaded Conditions

Table 5

Comparison between mean value of the maximum power for configurations with one bypass diode and two bypass diodes per module under random shading patterns.

Array sizeConfigurationMean value of maximum power (W)Difference in mean value of power (W)
One diode per moduleTwo diodes per module

6 × 4SP197.86218.8721.01
6 × 4TCT234.57262.2027.63
6 × 4BL184.48206.2021.72
6 × 4HC219.15245.6026.45