Research Article
Two-Stage Fault Diagnosis Method Based on the Extension Theory for PV Power Systems
Table 4
The results of the fault diagnosis by day in different ways.
| Test method | Learning times | Learning accuracy (%) | Test accuracy (%) |
| The proposed method | no | no | 100% | K-means clustering method | no | 69.17% | 62.5% | Multilayer neural network I (5-8-8) | 1000 | 85.83% | 83.33% | Multilayer neural network II (5-10-8) | 1000 | 87.5% | 86.67% | Multilayer neural network III (5-12-8) | 1000 | 93.33% | 92.5% |
|
|