Research Article

Research on the Comparison Analyses of Three-Phase Discrete and Integrated LC Filters in Three-Phase PV Inverter

Table 2

The comparison of the discrete magnetics, five-limb magnetics, and three-limb magnetics.

The number of magnetic coreThe cross section area of middle limbAir gap distributionInductanceThe number of turnsThe max flux density

Discrete filter inductorThree EE96/48/321024 mm2The air gap of middle limb is 2.0 mm; the air gaps of the other limbs are zeroSelf-inductance is 3.8 mH800.33 T
Integrated filter inductor (five limbs)Two EE96/48/321024 mm2The air gaps of middle three limbs are 2.0 mm; the air gaps of the other two limbs are zeroSelf-inductance is 3.8 mH800.33 T
Integrated filter inductor (three limbs)One EE96/48/321024 mm2The air gap of middle limb is 1.4 mm; the air gaps of the other limbs are 0.7 mmSelf-inductance is 3.8 mH; mutual inductance is 1.9 mH80Middle limb is 0.17 T; the other two limbs are 0.33 T