Research Article
Performances of an Interleaved High Step-Up Converter with Different Soft-Switching Snubbers for PV Energy Conversion Applications
Table 4
Parameter values of the boost converter with boost type snubber under full-load condition.
| Parameters | Formulas | Calculation values | Practical values |
| | | 38.87 A | 39 A | | | 54.47 A | 56 A | Switch stress | | 53 V | 55 V | Output diode stress | | 1120 V | 1500 V | Duty ratio D | | 0.325 | 0.34 | Switching loss of each switch at turn-on | | 0 W | 0 W | Switching loss of each switch at turn-off | | 7.43 W | 9.24 W | Conduction loss of each switch | | 28.58 W | 30.31 W | Conduction loss of diode | | 7.2 W | 7.5 W | Forward drop voltage of output diode | | 4.8 V () | 4.8 V | | | 87 ns | 100 ns | | | 103 ns | 120 ns | | | 36 V | 36 V | | | 400 V | 400 V | | | 20 μs | 20 μs | | | 3 A | 3 A | | | 20 | 20 | | | 6.5 μs | 6.8 μs | | | 0.04 Ω | 0.04 Ω |
|
|