Research Article
Development of a Wind Directly Forced Heat Pump and Its Efficiency Analysis
Table 2
Summation of the experimental condition for the winter model (heat pump operation).
| Experiment no. | 1 | 2 | 3 | 4 |
| Average wind speed (m/s) | 3 | 4 | 5 | 6 | Total duration (min) | 60 | 60 | 60 | 60 | Temperature change (°C) | 10 ~ 12.5 | 11 ~ 16.5 | 10 ~ 18.5 | 10 ~ 25 | Cooling energy, (kJ) | 293.02 | 644.64 | 996.27 | 1758.12 | Wind energy, (kJ) | 478.57 | 1134.38 | 2215.58 | 3823.53 | Working efficiency, | 61.23 | 56.83 | 44.96 | 45.98 |
| Climate condition | the outdoor temperature and the indoor | temperature both are 10°C |
|
|