Research Article
A Population Classification Evolution Algorithm for the Parameter Extraction of Solar Cell Models
Table 14
The extracted parameters for thin-film ST40 PV module by PCE at different temperatures and values of irradiance of 1000 W/m2.
| Parameters | Temperature | (25°C) | (40°C) | (55°C) | (70°C) |
| Thin-film ST40 | | | | | (A) | 2.596880 | 2.614915 | 2.632917 | 2.650986 | (μA) | 2.789916 | 11.564938 | 42.589211 | 140.543289 | (Ω) | 0.798689 | 0.799007 | 0.799080 | 0.799203 | (Ω) | 300.3258 | 299.6235 | 299.3048 | 297.4168 | | 1.499926 | 1.499275 | 1.499222 | 1.498911 | RMSE | | | | |
|
|