Research Article

A Population Classification Evolution Algorithm for the Parameter Extraction of Solar Cell Models

Table 14

The extracted parameters for thin-film ST40 PV module by PCE at different temperatures and values of irradiance of 1000 W/m2.

ParametersTemperature
(25°C)(40°C)(55°C)(70°C)

Thin-film ST40
(A)2.5968802.6149152.6329172.650986
(μA)2.78991611.56493842.589211140.543289
(Ω)0.7986890.7990070.7990800.799203
(Ω)300.3258299.6235299.3048297.4168
1.4999261.4992751.4992221.498911
 RMSE