Research Article
Performance Analysis of Solar Assisted Fluidized Bed Dryer Integrated Biomass Furnace with and without Heat Pump for Drying of Paddy
Table 2
Uncertainties of the parameters during drying experiment of paddy.
| Parameters | Unit | Uncertainty comment | SA-FBDIBF | SAHP-FBDIBF |
| Ambient air temperature | °C | ±0.17 | ±0.17 | Inlet air temperature of heat pump | °C | — | ±0.17 | Outlet air temperature of heat pump | °C | — | ±0.17 | Inlet air temperature of condenser | °C | — | ±0.17 | Outlet air temperature of condenser | °C | — | ±0.17 | Inlet air temperature of solar collector | °C | ±0.17 | ±0.17 | Outlet air temperature of solar collector | °C | ±0.17 | ±0.17 | Inlet air temperature of biomass furnace | °C | ±0.17 | ±0.17 | Outlet air temperature of biomass furnace | °C | ±0.17 | ±0.17 | Inlet air temperature of drying chamber | °C | ±0.17 | ±0.17 | Outlet air temperature of drying chamber | °C | ±0.17 | ±0.17 | Ambient air relative humidity | % | ±0.22 | ±0.22 | Inlet air relative humidity of heat pump | % | — | ±0.22 | Outlet air relative humidity of heat pump | % | — | ±0.22 | Inlet air relative humidity of drying chamber | % | ±0.22 | ±0.22 | Outlet air relative humidity of drying chamber | % | ±0.22 | ±0.22 | Inlet air absolute humidity of drying chamber | kg water/ kg dry air | ±0.26 | ±0.26 | Inlet air adiabatic saturation humidity of drying chamber | kg water/ kg dry air | ±0.26 | ±0.26 | Solar radiation | W/m2 | ±0.14 | ±0.14 | Air velocity | m/s | ±0.24 | ±0.24 | Mass loss of samples | g | ±0.014 | ±0.014 | Mass loss of products | kg | ±0.11 | ±0.11 | Reading values of table (, , CV, and ) | — | ±0.1–0.2 | ±0.1–0.2 | Time measurement | min | ±0.1 | ±0.1 |
|
|