Research Article
Energy Conversion and Transmission Characteristics Analysis of Ice Storage Air Conditioning System Driven by Distributed Photovoltaic Energy System
Table 2
Measuring instrument parameters and uncertainty.
| Instrument | Model | Range | Accuracy | Application scope | Maximum relative error | Maximum absolute error | Uncertainty ( class) |
| Pyranometer | Kipp & Zonen CMP-6 | 0–2000 (W/m2) | ±5% | 0–1000 (W/m2) | ±10% | ±100 W/m2 | 57.7348 W/m2 | Thermocouples | T | −200 to 350 (°C) | ±0.4% | 0–150 (°C) | ±0.93% | ±1.4°C | 0.8083°C | Wind speed transducer | EC-9S | 0–70 (m/s) | ±0.4% | 0–10 (m/s) | ±2.8% | ±0.28 m/s | 0.1617 m/s | Electromagnetic flow meter | KROHNE OPTIFLUX 5000 | DN 5; 0–12 (m/s) | ±0.15% | 0–5 (m/s) | ±0.36% | ±0.018 m/s | 0.0104 m/s | Pressure transducer | YOKOGAWA EJA430E | 0.14–16 (MPa) | ±0.055% | 0–2 (MPa) | ±0.44% | ±0.0088 MPa | 0.0051 MPa | Electronic balance | AHW-3 | 0–3 kg | ±0.05 g | 0–3 kg | ±0.05% | ±0.0015 kg | 0.0009 MPa | Wattmeter | DELIXI DDS607 | 0–10000 kW·h | ±0.01 kW·h | 0–100 kW·h | ±1% | ±1 kW·h | 0.5774 kW·h | Digital multimeter | FLUKE F-179 | Voltage: 0–1000 V | ±0.9% | 0–380 V | ±2.37% | ±9.006 V | 5.1996 V | Current: 0–10 A | ±1% | 0–10 A | ±1% | ±0.1 A | 0.0577 A |
|
|