Research Article

Experimental Analysis of the Potential Induced Degradation Effect on Organic Solar Cells

Table 6

Device 3 finger 5 time-dependent voltage degradation after O2 plasma application.

Light intensityExperimentIsc (mA/cm2)Voc (mV)FFVmp (mV)Imp (mA/cm2)Efficiency (%)Power losses (%)

100 mW/cm2Initial9,0925800,5294206,6452,791
6 min O2 plasma6,8405600,4813804,8461,84134,025