Evaluated irradiance coefficients of , and of seven different commercially available PV modules and evaluated parameters of seven different commercially available PV modules at NOCTC (45°C and 1000 W/m2) for the proposed model.

ModelParameterThin filmMonocrystallineMulticrystalline
Shell ST40FS-270Shell SQ 150-PCHIT-N240SE10KD140GX-LFBSKD260GX-LFB2KU265-6MCA

Proposed model0.0849560.0964900.0469210.0458820.0674770.0557810.055781
−0.093363−0.022004−0.0745120.012071−0.0397870.0198290.019829
0.0122620.058966−0.046283−0.0233650.0306710.0539820.044600
A2.1501600000.9918720003.8635199994.7067519997.0273280007.3592640007.496895999
1.755842.865951.672571.210161.745351.500151.49252
A1.5043 × 10−51.2555 × 10−42.4789 × 10−54.6055 × 10−95.6770 × 10−54.8923 × 10−64.6342 × 10−6
Ω1.217722.401330.243460.330970.028070.153160.14925
Ω1881.987914942.8904073.02563790.1388469.1091552.7469644.3563