Research Article

Evaluation of Energy Production and Energy Yield Assessment Based on Feasibility, Design, and Execution of 3 × 50 MW Grid-Connected Solar PV Pilot Project in Nooriabad

Table 10

Power generating prediction and net output [10000 kWh/year] for one-year period.

YearDegradation factorExpected attenuation rateExpected output per year (ten thousand kWh)

12.500%2.500%24970.89
20.625%3.125%24346.62
30.625%3.750%24190.55
40.625%4.375%24034.49
50.625%5.000%23878.42
61.000%6.000%23722.35
71.000%7.000%23472.64
81.000%8.000%23222.93
91.000%9.000%22973.22
101.000%10.000%22723.51
110.625%10.625%22473.81
120.625%11.250%22317.74
130.625%11.875%22161.67
140.625%12.500%22005.60
150.625%13.125%21849.53
160.625%13.750%21693.46
170.625%14.375%21537.40
180.625%15.000%21381.33
190.625%15.625%21225.26
200.625%16.250%21069.19
210.625%16.875%20913.12
220.625%17.500%20757.06
230.625%18.125%20600.99
240.940%19.065%20444.92
250.935%20.000%20210.19

Total20.00%558176.91
Average22327.08