Research Article

Evaluation of Energy Production and Energy Yield Assessment Based on Feasibility, Design, and Execution of 3 × 50 MW Grid-Connected Solar PV Pilot Project in Nooriabad

Table 5

Detail of PV module parameters.

NOCTDataElectrical parameterData

Max. power217.80 WRated max. power at STC300 W
Open circuit voltage42.31 VOpen circuit voltage45.20 V
Max. power voltage33.77 VMax. power voltage36.41 V
Short circuit current6.93 AShort circuit current8.73 A
Max. power current6.53 AMax. power current8.24 A
Condition20°C, 1 m/sModule efficiency15.48%