Specifications of the solar chimney and the thermo-physical properties of PCM.
| Cover |
| Material | Glass | Dimension | 1500 × 1000 × 8 mm | Surface coating | 0.90 | Absorber | Plate | Aluminum | Thickness | 2 mm | Surface coating | 0.94 | PCMs | Myristoyl Dodecylic acid Myristelaidic acid Palmitic acid | Melting temperature | 38°C, 44°C, 50°C, 63°C | Thickness of PCM | 40 mm | Gap | Absorber plate to glass | 200 mm | Insulation material | Extruded insulation panels | 30 mm |
|
|