Research Article
Grid-Connected Photovoltaic System with Active Power Filtering Functionality
Table 1
Simulation and experimental parameters.
| Photovoltaic array | | Maximum power | 200 W | Open-circuit voltage | 92 V | Short-circuit current | 4.76 A | Nominal voltage (MPP) | 67 V | Nominal current (MPP) | 3.6 A | Topology | | DC/DC boost converter inductor | 3.5 mH | DC link voltage | 250 V | Energy storage capacitor | 330 μF | Output inductor | 4 mH | DC/DC boost converter switching frequency | 39 kHz | Inverter switching frequency | 90 kHz | PI controller | | Gain | 0.05 | Time constant | 0.05 | Nonlinear load | | Power factor | 68% | Apparent power | 105 VA | Grid | | Frequency | 60 Hz | Grid voltage | 120 V rms |
|
|