Manufacturers, models, and precisions of monitoring devices.

DeviceSpecificationPrecision

Power sensorWBI021S91
(Weibo, China)
0.5%
PyranometerTQB-2
(Sunlight, China)
≤2%
Thermocouple0.2 mm T-type
(USTC, China)
Data collection34970A
(Agilent, USA)
/
Pressure sensorP3308
(Germany)
≤0.5% of FS