Research Article

Hardware Implementation of a Fuzzy Logic Controller for a Hybrid Wind-Solar System in an Isolated Site

Table 7

Performance comparison between proposed work and other works.

ReferencesAlgorithmsTracking efficiency ηMPPT (%)Response time (s)

Proposed algorithmFuzzy logic99.610.40

Izadbakhsh et al. [23]ANFIS for solar fuzzy logic for wind subsystems99.340.80

Suresh and Dhandapani [3]Fuzzy logic99.400.58
HC and P&O98.321.7

Rezvani et al. [4]Fuzzy logic without load99.250.80
Fuzzy logic with load1.1

Belmili et al. [5]Fuzzy logic99.220.80
P&O96.982.95