Research Article
Study of Temperature Coefficients for Parameters of Photovoltaic Cells
Table 1
The absolute temperature coefficients for the important parameters of the photovoltaic cells.
| PV | (W/m2) | (mV °C−1) | (mA °C−1) | (mW °C−1) | (% °C−1) |
| mSi | 400 | −2.36 | 0.265 | −0.251 | −0.138 | 600 | −2.32 | 0.375 | −0.419 | −0.141 | 800 | −2.27 | 0.465 | −0.551 | −0.147 | 1000 | −2.24 | 0.537 | −0.691 | −0.162 |
| pSi | 400 | −2.29 | 0.108 | −0.07 | −0.122 | 600 | −2.27 | 0.147 | −0.103 | −0.130 | 800 | −2.24 | 0.191 | −0.128 | −0.139 | 1000 | −2.19 | 0.215 | −0.163 | −0.147 |
| aSi | 400 | −8.53 | 0.00727 | −0.0101 | −0.026 | 600 | −8.36 | 0.0106 | −0.0158 | −0.031 | 800 | −8.3 | 0.0151 | −0.0208 | −0.0411 | 1000 | −8.09 | 0.0187 | −0.0268 | −0.0487 |
| InGaP/InGaAs/Ge | 400 | −7.46 | 0.0125 | −0.016 | −5.49E − 4 | 600 | −7.21 | 0.0158 | −0.027 | −5.6E − 4 | 800 | −7.05 | 0.0194 | −0.032 | −5.76E − 4 | 1000 | −6.93 | 0.0253 | −0.040 | −5.99E − 4 |
|
|