Research Article
Experimental Study of a Novel Direct-Expansion Variable Frequency Finned Solar/Air-Assisted Heat Pump Water Heater
Table 5
Average COP and heating time under different ambient and operation conditions.
| Ambient conditions | Compressor frequency | Average COP | Heating time (min) | Ambient temperature | Solar irradiation | Air | Dual | Solar | Air | Dual | Solar |
| 20°C | 900 W/m2 | 30 Hz | 2.23 | 2.65 | 3.35 | 382.2 | 328.8 | 336.3 | 45 Hz | 3.37 | 2.54 | 3.29 | 191.9 | 186.7 | 237.3 | 60 Hz | 3.85 | 3.66 | 2.92 | 129.7 | 139.3 | 201.4 |