Research Article

Grid-Connected Semitransparent Building-Integrated Photovoltaic System: The Comprehensive Case Study of the 120 kWp Plant in Kunming, China

Table 4

The calculated results with different mounting tilt angles.

Tilt angles90°85°80°70°60°

Annual power production (MWh)68.68575.51582.35995.617107.311
EPBT (years)10.329.388.607.416.60
Environmental cost of generation (RMB yuan/kWh)1.158 × 10−21.053 × 10−20.965 × 10−20.832 × 10−20.741 × 10−2
Payback period (years)1715141211
NPV (RMB yuan)272,820359,347446,053614,015762,164