Research Article
Grid-Connected Semitransparent Building-Integrated Photovoltaic System: The Comprehensive Case Study of the 120 kWp Plant in Kunming, China
Table 4
The calculated results with different mounting tilt angles.
| Tilt angles | 90° | 85° | 80° | 70° | 60° |
| Annual power production (MWh) | 68.685 | 75.515 | 82.359 | 95.617 | 107.311 | EPBT (years) | 10.32 | 9.38 | 8.60 | 7.41 | 6.60 | Environmental cost of generation (RMB yuan/kWh) | 1.158 × 10−2 | 1.053 × 10−2 | 0.965 × 10−2 | 0.832 × 10−2 | 0.741 × 10−2 | Payback period (years) | 17 | 15 | 14 | 12 | 11 | NPV (RMB yuan) | 272,820 | 359,347 | 446,053 | 614,015 | 762,164 |
|
|