Research Article
Photovoltaic Energy-Assisted Electrocoagulation of a Synthetic Textile Effluent
Table 2
Characterization of solar PV modules.
| Parameter | 1 PV module | 2 PV module |
| Solar irradiance (W/m2) | 1007.3 | 1046.5 | Ambient temperature (°C) | 25 | 25 | Cell temperature (°C) | 58.4 | 57 | Short current (A) | 4.4 | 9.0 | Open voltage (V) | 18.5 | 18.8 | Max power (W) | 51.5 | 107.3 | Max power current (A) | 3.8 | 7.9 | Max power voltage (V) | 13.5 | 13.6 | Fill factor (FF) | 0.63 | 0.63 |
|
|