Research Article

Optimal Design Method of a Hybrid CSP-PV Plant Based on Genetic Algorithm Considering the Operation Strategy

Table 8

Impact of rated output power on CSP-PV system.

85%90%95%100%

Annual output power (MWh)328957399050375695384810
LCOE ($/kWh)0.05920.05610.05550.0530
CSP
Capacity of heat storage (MWh)145.613254.971136.059166.577
Annual output power of CSP system (MWh)69925803296665974099
Annual utilization hours of CSP system (h)2331267822222470
PV
Installed capacity of PV system (MW)78.42399.805242.95497.555
Capacity of battery (MWh)10.06111.2748.9775.752
Annual output power of PV system (MWh)259032318721309036310711
Annual utilization hours of PV system (h)3303319332013185