Research Article

Research on Parameter Distribution Features of Photovoltaic Array under the Cover and Shadow Shading Conditions

Table 5

Error analysis for computation result.

Shading type (V) (V) (V) (V) (%) (%) (W/m2) (°C)

Normal87.0108.488.2109.81.3%1.3%98236
Shadow 177.4108.678.1109.00.8%1.0%93235
Shadow 277.2108.578.1109.31.1%1.1%93635
Shadow 369.1108.868.3110.31.1%1.1%94534
Shadow 476.5108.477.9109.61.7%1.0%93136
Shadow 566.7108.367.9109.31.8%1.0%93936
Shadow 657.4108.357.9109.10.8%1.1%93636
Cover 177.197.478.197.811.3%0.4%97336
Cover 277.696.178.398.030.9%1.9%97335
Cover 368.187.168.486.080.3%1.1%95234
Cover 477.898.378.598.230.8%0.1%94233
Cover 567.983.868.385.250.5%1.7%96335
Cover 658.674.258.173.690.9%0.6%95936

The data of shading voltage under different conditions and the relative error between the measured occlusion voltage and the theoretical occlusion voltage.