Research Article
Investigation of Repurposed Material Utilization for Environmental Protection and Reduction of Overheat Power Losses in PV Panels
Table 2
Calculations of the fins’ effectiveness.
| Area of PV panel | 0.156 m2 | Ambient temperature | 25°C | Heat convection coefficient () | 3.06 W m-2 K-1 | Length of the fin () | 0.15 m | Width of the fin () | 0.31 m | Thickness of fin () | 0.001 m | Material’s thermal conductivity () | 237 W m-1 K-1 | Number of fins | 21 | Finned area | 1.56 m2 | Unfinned area | 0.15 m2 | Heat rate from the finned area () | 110.8 W | Heat rate from the unfinned area () | 10.117 W | Backside temperature of PV panel | 47°C | Fin’s cross-sectional area () | 0.00031 m2 | The effectiveness of fin () | 11.455 | The efficiency of the fin () | 84.2% |
|
|