Multiple DGs for Reducing Total Power Losses in Radial Distribution Systems Using Hybrid WOA-SSA Algorithm

Table 3

Active and reactive constant loads on an IEEE 123-bus test system.

Bus no.PhasesActive load (kW)Reactive load (kVAr)Load typeBus no.PhasesActive load (kW)Reactive load (kVAr)Load type

1a3020Wye62c2520Wye
2b1210Wye63a2720Wye
4c2620Wye64b5035Wye
5c1310Wye65a2325Delta
6c2520Wye65b2425Delta
7a1410Wye65c5250Delta
9a2420Wye66c5235Wye
10a1310Wye68a1210Wye
11a2620Wye69a2520Wye
12b1410Wye70a1310Wye
16c2620Wye71a2620Wye
17c1210Wye73c2720Wye
19a2620Wye74c2820Wye
20a2620Wye75c2820Wye
22b2520Wye76a6280Delta
24c2620Wye76b4650Delta
28a2820Wye76c4550Delta
29a2820Wye77b2620Wye
30c2420Wye79a2720Wye
31c1310Wye80b3020Wye
32c1410Wye82a2920Wye
33a2620Wye83c1210Wye
34c2520Wye84c1310Wye
35a2820Delta85c2520Wye
37a2820Wye86b1310Wye
38b1210Wye87b2720Wye
39b1310Wye88a2920Wye
41c1210Wye90b2920Wye
42a1310Wye92c2420Wye
43b2520Wye94a2620Wye
45a1510Wye95b1410Wye
46a1410Wye96b1310Wye
47a, b, c6475Wye98a2620Wye
48a, b, c137150Wye99b3020Wye
49a2325Wye100c2820Wye
49b4550Wye102c1210Wye
49c2320Wye103c2720Wye
50c2920Wye104c2620Wye
51a1510Wye106b2520Wye
52a2520Wye107b2520Wye
53a2620Wye109a2920Wye
55a1310Wye111a1510Wye
56b1310Wye112a1110Wye
58b1310Wye113a2520Wye
59b1510Wye114a1310Wye
60a1410Wye
Total34901920