Research Article
Form and Operation Mode Analysis of a Novel Solar-Driven Cogeneration System with Various Collector Types
Table 3
Comparison of the calculation model and the experiment.
| Parameters | Experiment | Calculation model | Relative error |
| (°C) | 95.03 | 95.03 | / | Flow rate of heat source (t/h) | 77.94 | 77.94 | / | (°C) | 74.08 | 74.08 | / | (°C) | 25 | 25 | / | (°C) | 23.39 | 23.39 | / | (°C) | 30.41 | 30.41 | / | (°C) | 76.62 | 77.08 | 0.60% | (°C) | 32.41 | 32 | −1.27% | (kW) | 1905 | 1905 | / | (kW) | 1736 | 1703 | −1.90% | (kW) | 151.35 | 154.94 | 2.37% | (kW) | 8.83 | 8.57 | −2.94% | (kW) | 141.86 | 146.37 | 3.18% | (%) | 7.45 | 7.68 | 3.09% |
|
|