Research Article
Investigation of Daytime Peak Loads to Improve the Power Generation Costs of Solar-Integrated Power Systems
Table 1
Characteristics of the ten thermal generation units [
19].
| Unit | Power limits | Fuel cost coefficients | Ramp rate limits | (MW) | (MW) | | | | | | (MW/h) | (MW/h) |
| 1 | 150 | 470 | 0.00043 | 21.6 | 958.2 | 450 | 0.041 | 80 | 80 | 2 | 135 | 460 | 0.00063 | 21.05 | 1313.6 | 600 | 0.036 | 80 | 80 | 3 | 73 | 340 | 0.00039 | 20.81 | 604.97 | 320 | 0.028 | 80 | 80 | 4 | 60 | 300 | 0.0007 | 23.9 | 471.6 | 260 | 0.052 | 50 | 50 | 5 | 73 | 243 | 0.00079 | 21.62 | 480.29 | 280 | 0.063 | 50 | 50 | 6 | 57 | 160 | 0.00056 | 17.87 | 601.75 | 310 | 0.048 | 50 | 50 | 7 | 20 | 130 | 0.00211 | 16.51 | 502.7 | 300 | 0.086 | 30 | 30 | 8 | 47 | 120 | 0.0048 | 23.23 | 639.4 | 340 | 0.082 | 30 | 30 | 9 | 20 | 80 | 0.10908 | 19.58 | 455.6 | 270 | 0.098 | 30 | 30 | 10 | 55 | 55 | 0.00951 | 22.54 | 692.4 | 380 | 0.094 | 30 | 30 |
|
|