Research Article

Cascaded H-Bridge MLI and Three-Phase Cascaded VSI Topologies for Grid-Connected PV Systems with Distributed MPPT

Table 1

The system parameter.

The system parameters used for simulation
DC-link capacitor4 mF
Grid interface inductor 4.2 mH
DC-DC Ćuk converter switching frequency 40 kHz
Inverter switching frequency 1.5 kHz
Grid-rated RMS voltage120 V
Reference voltage of configuration A70 V
Reference voltage of configuration B150 V
Reference voltage of configuration C110 V
The system parameters used for experiment
DC-link capacitor4 mF
Grid interface inductor 4.2 mH
DC-DC Ćuk converter switching frequency 40 kHz
Inverter switching frequency 1.5 kHz
Reference voltage of configurations A, B, and C40 V
Grid-rated RMS voltage of configuration A55 V
Grid-rated RMS voltage of configuration B33 V
Grid-rated RMS voltage of configuration C44 V