Research Article

Performance Modelling of Dual Air/Water Collector in Solar Water and Space Heating Application

Table 1

Main parameters of the dual air/water solar collector.

Collector parameterValueCollector parameterValue

Dimensions (W/L/H)Absorber emissivity0.05
Area (gross, aperture, absorber)1.6 m2, 1.52 m2, 1.49 m2Header pipeCu
Cover materialSolar glass 4 mmNumber of riser tubes10
Front air gap thickness30 mmDistance between riser pipes100 mm
Absorber materialAluminium 0.4 mmAir flow channel10 mm
Cover transmittance0.92Back insulation thickness40mm
Absorber absorptance0.95Insulation materialRockwool