Research Article

Experimental Investigation of a Direct Evaporative Cooling System for Year-Round Thermal Management with Solar-Assisted Dryer

Table 2

Specifications of the measuring instruments.

InstrumentParameterDeviceRangeAccuracy

Load cellMass of vermicompostLoad cell module ITB-04CE0-5 kg1.5% of full-scale division
Digital vane anemometerVelocity of airLutron AM42010.4 ms−1 to 30 ms−1±2%
Digital hygro thermometerTemperature and RH of airDHT 22Temp: -40°C to 80°C
RH: 0% to 100%
Temp: ±0.5°C
RH: ±2%