Review Article

Analytical versus Metaheuristic Methods to Extract the Photovoltaic Cells and Panel Parameters

Table 6

The parameters and statistical tests for the STM6-40 photovoltaic panel.

Algorithm (A) (A) () RMSEAE

HSDA [44]1.66390477991.738654397854.7308990.153855932543.418349850.02190350.99997731
Rcr-IJADE [36]1.66391.738754.73080.1548573.41880.02161480.99997719
ITLBO [59]1.66391.738754.73080.1548573.41880.02161480.99997719
5Pm [3]1.663633.35340.9121898.160.5409480.98999793