Research Article
Sizing Algorithm for a Photovoltaic System along an Urban Railway Network towards Net Zero Emission
Table 5
Number of photovoltaic (PV) panels and energy generation of different options.
| Case | No. of panels | Average daily generation (MWh) | Area (m2) |
| PV panel on the rail track | 9300 | 15.30 | 18664 | PV panels above the overhead line () | 1500 | 2.48 | 3010 | PV panels above the overhead line () | 3000 | 4.95 | 6020 | PV panels above the overhead line () | 4500 | 7.43 | 9031 | PV panels above the overhead line () | 6000 | 9.90 | 12042 | PV panels above the overhead line () | 7500 | 12.40 | 15052 | PV panels above the overhead line () | 9000 | 14.90 | 18062 |
|
|