Research Article
Sizing Algorithm for a Photovoltaic System along an Urban Railway Network towards Net Zero Emission
Table 6
Comparison of the number of photovoltaic panels required for the cases considered.
| Description | Energy (kWh) | No. of PV panels | | 2017 | 2018 | 2020 | 2017 | 2018 | 2020 |
| Average (DC1) | 1559.7 | 1622.1 | 1672.9 | 3270 | 3145 | 3049 | 80% (DC2) | 1138.1 | 1238.7 | 1202.2 | 4482 | 4118 | 4243 | 75% (DC3) | 1237.6 | 1312.1 | 1300.1 | 4121 | 3887 | 3923 | 70% (DC4) | 1322.0 | 1377.8 | 1430.0 | 3858 | 3702 | 3567 | 65% (DC5) | 1386.6 | 1464.1 | 1490.3 | 3679 | 3484 | 3423 | 60% (DC6) | 1482.3 | 1524.3 | 1566.2 | 3441 | 3346 | 3257 | 55% (DC7) | 1541.9 | 1610.9 | 1614.0 | 3308 | 3166 | 3160 | 50% (DC8) | 1608.4 | 1657.3 | 1717.4 | 3171 | 3078 | 2970 |
|
|