Research Article

Sizing Algorithm for a Photovoltaic System along an Urban Railway Network towards Net Zero Emission

Table 7

Percentage excess generation with number of panels calculated based on 2017, 2018, and 2020 data.

2017 data-based design2018 data-based design2020 data-based design

Average (DC1)0.04.07.3-3.80.03.2-6.8-3.00.0
80% (DC2)37.142.647.025.931.035.129.834.939.2
75% (DC3)26.031.135.218.923.627.520.024.828.7
70% (DC4)18.022.726.613.217.721.49.113.417.0
65% (DC5)12.517.020.76.510.814.34.78.912.3
60% (DC6)5.29.412.92.36.49.8-0.43.66.8
55% (DC7)1.25.28.5-3.20.73.9-3.40.53.7
50% (DC8)-3.00.94.0-5.9-2.11.0-9.2-5.5-2.6