Research Article

Sizing Algorithm for a Photovoltaic System along an Urban Railway Network towards Net Zero Emission

Table 8

Percentage of space utilization of the proposed photovoltaic systems.

CasePercentage space utilization
2017 data-based design2018 data-based design2020 data-based design

3rd railOverhead3rd railOverhead3rd railOverhead
Average (DC1)35.272.733.869.932.867.8
80% (DC2)48.299.644.391.545.694.3
75% (DC3)44.391.641.886.442.287.2
70% (DC4)41.585.739.882.338.479.3
65% (DC5)39.681.837.577.436.876.1
60% (DC6)37.076.536.074.435.072.4
55% (DC7)35.673.534.070.434.070.2
50% (DC8)34.170.533.168.431.966.0