| Configuration | Grid (kW) | PV (kW) | Wind (kW) | DG (kW) | Converter (kW) | Total capital cost ($) | Total NPC ($) | Operating cost ($/yr.) | COE ($/kWh) | Renewable fraction |
| G-PV-W | 1,000 | 20 | 20 | 0 | 20 | 49,580 | 4,42,090 | 30,705 | 0.091 | 0.22 | G-W | 1,000 | 0 | 20 | 0 | 0 | 24,300 | 4,52,301 | 33,481 | 0.093 | 0.14 | G-PV | 1,000 | 20 | 0 | 0 | 20 | 25,280 | 4,74,851 | 35,168 | 0.098 | 0.08 | G | 1,000 | 0 | 0 | 0 | 0 | 0 | 4,85,255 | 37,960 | 0.1 | 0 | G-DG-PV-W | 1,000 | 20 | 20 | 144 | 20 | 59,794 | 6,76,241 | 48,223 | 0.139 | 0.22 | G-DG-W | 1,000 | 0 | 20 | 144 | 0 | 34,514 | 6,85,524 | 50,926 | 0.141 | 0.14 | G-DG-PV | 1,000 | 20 | 0 | 144 | 20 | 35,494 | 7,07,979 | 52,606 | 0.146 | 0.08 | G-DG | 1,000 | 0 | 0 | 144 | 0 | 10,214 | 7,17,976 | 55,366 | 0.148 | 0 |
|
|