Research Article

Corrosion Reason Analysis of 13Cr110 Tubing in an Injection and Production Well of the Suqiao Gas Storage Group

Table 3

Test results of Charpy impact performance of tubing.

SamplesTemperature (°C)Absorbed energy (J)Shear section rate (%)
NumberSize (mm)Notch shape

84#V0116108107100100100
258#131129128100100100
259#128134121100100100
364#131131121100100100
API SPEC 5CT standard≥22.55/